Compensatory Stepping Correction (D20)

AIM:

To assess postural instability in Parkinson’s disease using the Compensatory Stepping Correction item from the Mini-BESTest.

Compensatory Stepping Correction

Additional Information

RATIONALE:

Postural instability is a common motor impairment in people with Parkinson’s disease. This test assesses the patient’s reactive postural control by evaluating their ability to recover from a sudden loss of support.

EQUIPMENT:

None

KEY POINTS:

  • Test all directions – forwards, backwards, left and right.
  • Use the Mini-BESTest criteria (see manual) to score the patient’s response.
  • Ensure the therapist is positioned to steady the patient if necessary, but not to interfere with recovery steps taken by the patient.
  • For patients at risk of falling during the test, have another person nearby to help steady the patient, or conduct the test with the patient wearing a safety harness.

COMMON ERRORS:

Therapist does not stay close enough after releasing the patient to steady them if necessary, or stays too close and interferes with the patient’s steps.

PROGRESSION AND VARIETY:

Not applicable (as this test is performed in a standardised manner.)